5. Mount the Toe Kick Panel on both sides of the unit into
the extruded dimples using the (4) T-20 Torx drill point
screws provided.
Figure 23: Toe Kick Panel Installation
Data Rating Label
The data rating label shows the model and serial number of
the range. It is located on a slide out plate under the range
(Figure 24). The slide out plate can be accessed by first
removing the door trim as shown below.
The electric wiring diagrams and schematics are attached
behind the door trim, and should not be removed except by
a service technician, then replaced after service.
Installation Instructions
Figure 24: Rating Label Location
STEP 10: Burner Test
Install any loose components, such as burner caps and
grates, that may have been removed earlier. Be certain that
burner caps seat properly into the burner bases. Before
testing operation of the appliance, verify that the unit and
the gas supply have been carefully checked for leaks and
that the unit has been connected to the electrical power
supply. Turn the manual gas shut-off valve to the open
position.
NOTICE: All oven knobs and selectors must be set to OFF
before powering up the range. To prevent unintended
operation at power up, please set all oven knobs to OFF.
To ensure customer safety in the event of power failure, the
unit will display an error message upon reinstatement of
power unless all oven knobs are set to OFF. Set all oven
knobs to OFF and reset the breaker to clear the message.
Test Rangetop Burners
Test Burner Ignition
Select a rangetop burner knob. Push in and turn
counterclockwise to HI. The ignitor/spark module will
produce a clicking sound. Once the air has been purged
from the supply lines, the burner should light within four (4)
seconds.
Test Flame: High Setting
Turn burner on to HI. See Figure 25 for appropriate flame
characteristics.
If any of the rangetop burners continue to burn mostly or
completely yellow, verify that the burner cap is positioned
properly on the burner base, then retest. If flame
characteristics do not improve, call THERMADOR service.
Test Flame: Simmer Setting
Turn burner on to SIM. Verify that the flame completely
surrounds the burner. There should be a flame at each
burner port and there should be no air gap between the
flame and the burner. Fan each of the flames out and allow
to reignite to verify burner reignition. If any burners do not
carry over, call THERMADOR service.