Pressure Sensors with IO-Link
BSP-B... /-V...
Mechanical installation
Adapter for process connection G 1/4"
Pressure sensors BSP can be adapted to different process
connections using adapters (accessories) available as an
optional extra. The adapters must be ordered separately.
Adapters for other process connections are available on
request.
Adapter G 1/4" per EN 3852
Ordering code BAM01KP
Stainless steel
Connection:
- Sensor-side: G 1/4"
- Process-side: G 1/4"
Torque approx. 5 Nm
Adapter NPT 1/4"
Ordering code BAM01KT
Stainless steel
Connection:
- Sensor-side: G 1/4"
- Process-side: NPT 1/4"
Torque approx. 30 Nm
Adapter G 1/4" per EN 837
(for attachment to pressure
gauge)
Ordering code BAM01KR
Stainless steel
Connection:
- Sensor-side: G 1/4"
- Process-side: G 1/4"
Torque approx. 20 Nm
4
English

Electrical installation

Caution!
Always depressurize and disconnect pressure
sensors from the power supply before establish-
ing an electrical connection.
Establish the electrical connection to the device according
to the specifications indicated on the type plate and the
wiring diagrams below.
Connector housing
Fig. 8: Sensor circuit diagram with 2 switching outputs
Connector housing
Fig. 9: Sensor circuit diagram with analog output current
Connector housing
Fig. 10: Sensor circuit diagram with analog amperage output
Standard IO Mode
IO-Link communica-
tion mode
Standard IO Mode
IO-Link communica-
tion mode
Standard IO Mode
IO-Link communica-
tion mode