Pressure Sensors with IO-Link
BSP-B... /-V...

IO-Link interface

General device info
Baud rate
Input of process data length
Minimum cycle time
IO-Link version
SIO Mode
SIO Mode
Balluff pressure sensors with IO-Link support both SIO
Mode and IO-Link Mode.
SIO Mode (standard IO mode)
In SIO Mode, the sensor works like a normal pressure
sensor with standard output signals.
Pin 4 (output 1) of the M12 plug is always a digital output.
An additional digital output or an analog output is available
on pin 2 (output 2), depending on the selected version.
IO-Link Mode (communication mode)
If the sensor operates subordinate to an IO-Link master,
then the pressure sensor switches to IO-Link communica-
tion mode. The IO-Link communication now runs via pin 4
of the M12 plug.
Process data
The process data length of the pressure sensor is 16 bits.
The switching statuses of the two switching outputs
(BCD1 and BCD2) are transmitted in the process data, as
well as the current measured value.
The 14 bits of the measured value are scaled correspond-
ing to the measuring range of the sensor.
15
14....2
bits
Measured value
Measuring
Value range
range
–1...2 bar
–1000...2000
–1...10 bar
–100...1000
0...2 bar
0...2000
0...5 bar
0...5000
0...10 bar
0...1000
0...20 bar
0...2000
0...50 bar
0...5000
0...100 bar
0...1000
0...250 bar
0...2500
0...400 bar
0...4000
0...600 bar
0...6000
www.balluff.com
COM 2 (38.4 kbaud)
2 bytes
5 ms
V1.1
Yes
1
0
Multiplier
x0.001
x0.01
x0.001
x0.1
x0.01
x0.01
x0.01
x0.1
x0.1
x0.1
x0.1
Error and event codes
Error codes
Error code
0x8011
0x8012
Subindex not available
0x8023
0x8030
Parameter value out of range
0x8033
Parameter length overrun
0x8034
Parameter length underrun
Event codes
Definition
Event
codes
IO-Link
IO-Link
1.1
No malfunction 0x0000
0x0000
General mal-
0x1000
0x1000
function.
Unknown error
Process
0x8C10
0x8C10
variable range
overrun.
Process data
uncertain
Process
0x8C30
0x8C10
variable range
underrun.
Process data
uncertain
Description
Index not available
Access denied
Event
Device
Type
codes
status
1.0
0
Notifica-
tion
4
Error
2
Warning
2
Warning
English
9