5.9 - Memorisation of a climate sensor connected via radio
To perform the procedure you must have a transmitter ("old") already memorised in "Mode 1".
01. (on the climate sensor) Keep the yellow key pressed for 10 seconds and then release it (in this case the motor does not perform any movement).
02. (on the old transmitter) Press any key which has already been memorised three times (the motor will start performing the manoeuvre associated with that key).
03. (on the climate sensor) Keep the yellow key pressed for 2 seconds: the motor performs 3 movements to confirm the memorisation. Warning! If the motor
performs 6 movements, it means that its memory is full.
01
"P1"
Note – When performing the procedure, you can cancel it at any time by keeping the n and t keys pressed simultaneously for 4 seconds. Otherwise, do not press
any key and wait 60 seconds for the motor to perform 6 movements.
5.10 - Total or partial deletion of memory
This procedure allows you to choose under point 05 the data that you want to delete.
5.10.1 - Procedure performed with a transmitter memorised in "Mode I"
01. Keep the n key pressed and wait for the motor to perform 2 movements. Upon completion, release the key.
02. Keep the s key pressed and wait for the motor to perform 3 movements. Upon completion, release the key.
03. Keep the n key pressed and wait for the motor to perform 3 movements. Upon completion, release the key.
04. Keep the t key pressed and wait for the motor to perform 3 movements. Upon completion, release the key.
05. • To cancel the entire memory: Keep the s and t keys pressed and wait for the motor to perform five movements. Upon completion, release the keys.
• To delete only the memorised transmitters: do not press any key and wait until the motor performs five movements.
• To delete only the limit switch heights ("0", "1") and intermediate heights ("H"): WARNING: – This deletion must be performed only when you want
to adjust the limit switch heights again, using a different procedure than the one used previously. Keep the n key pressed and wait for the motor to per-
form 5 movements. Upon completion, release the key.
01
5
sec.
2
04
5
sec.
WARNING:
This deletion must be performed only when you
want to adjust the limit switch heights again,
using a different procedure than the one used
previously. Whereas if you want to adjust heights
with the same procedure, it is not necessary to
delete them from memory.
Note – When performing the procedure, you can cancel it at any time by keeping the n and t keys pressed simultaneously for 4 seconds. Otherwise, do not press
any key and wait 60 seconds for the motor to perform 6 movements.
7 – English
02
"P1"
10
sec.
Old
02
5
sec.
3
example
03
X 3
0,5
sec.
03
3
05
all
data
05
only
05
"0"
"1"
"H"
"P1"
2
sec.
5
sec.
3
5
sec.
5
THE
END
END
5
5
sec.
5
THE
END
END
3
THE
END
END
THE
END
END