Initial operation of Turbelle® powerhead
Operate the pump on mains of 230 VAC, 50 Hz
(USA: 115 VAC, 60 Hz).
Turbelle® powerhead can be connected to a time
switch, such as TUNZE® Theben-Timer 7080. It
can be switched on and off every quarter of an hour
during the day.
Conventional switching units, such as Wavemakers,
et cetera, are unsuitable. They considerably
increase the wear of the drive and may lead to the
exclusion of guarantee for the pump.
Thermostat shut-down
If the motor of the Turbelle® is overloaded by the
pump being blocked by a foreign body, for example,
the protective thermostat installed will interrupt the
power supply. After the motor has cooled down,
it is switched on again automatically. When this
happens, remove the mains plug from the socket
first of all, and then determine and remove the
cause of the overload.