6
Cleaning and maintenance
3. Release the distribution hose on
the door by pulling it lightly from
the inside of the door towards
the outside 2 and pressing to the
left 3 so that it clicks out of the
fastener. The dispensing unit
can now be removed and the
interior is easily accessible.
3
2
4. Thoroughly clean the coffee
dispensing unit from the inside
and outside with warm water
and a suitable brush to remove
any coffee residue and prevent
mould from forming.
Disconnect and clean
the hose distribution
system of the coffee
C
dispensing unit (only
if necessary, e.g,
clogging), see sec-
tion 6.6.
5. Reinsert the coffee dispensing
unit, see section 6.7.
52 / 233 EN
1
4
Fully Automatic Coffee Maker / User Manual
6.6 Cleaning the
hose distribution

system

1. Grip the loose hose end near
to the spring and pull the cross
shaped hose connector 1 out of
its fixing. Subsequently pull both
hose ends with the sleeve ends
out of the dispensing tubes 2.
2
2. Pull the sleeves out of the hoses
A and disconnect the hoses from
the connecting piece C. Pull the
hose together with the spring C
from the connecting piece.
3. Leave the parts immersed in a
milk cleaning solution for several
hours. Refer to the instructions
on the cleaning solution for the
exact quantity.
4. Subsequently clean the parts
with the solution and rinse them
thoroughly with clean water.