Combustion Air; Adding Vent Sections - Continental Fireplaces CDVS280N Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

28

4.7.4 combustion air

This appliance needs air for safe operation and must be installed in such a way that adequate combustion air is
available.
EN

4.7.5 adding vent sections

Add chimney sections, according to the manufacturers installation instructions. The chimney must extend at
least, 3 feet (1m) above its point of contact with the roof and at least 24 inches (61cm) higher than any wall,
roof, building or obstacle within 10 feet (3m) horizontally.
3 FT
(1m)
MIN
W415-1429 / C / 12.05.17
24" (61cm) MIN
10 FT (3m)
TO NEAREST
ROOFLINE
10 FT (3m)
OR MORE
FLAT ROOF
REV B : Added metric dimensions
LESS THAN
10 FEET
(3m)
24" (61cm)
RIDGE
MIN
3 FT (1m)
3 FT (1m)
MIN
MIN
3 FT (1m)
MIN
LESS THAN
10 FEET
(3m)
24" (61cm)
MIN
WALL
59.1B