Trouble shooting
Cause or check points
Phenomenon
I
s the air filter dirty?normally it should be cleaned every 15 days.
Are there any ostacles before inlet and outlet?
Is temperature set correctly ?
Are there some doors or windows left open?
Is there any direct sunlight through the window during the cooling
Poor cooling or poor
operation(use curtain)
heating
Are there too much heat sources or too many people in the room
during cooling operation?
IS the horizontal flap direction right?
It should be kept horizontal or upward during cooling operation
while set horizontal or downward during heating operation.
Water leakage
The air filter is dirty .The unit is tilt installed.
During unit operation or at stop, a swishing or gurgling noise may be
A swishing or gurgling noise
heard .At first 2-3 minutes after unit start, this noise is more noticeable
is heard
(This noise is generated by refrigerant flowing in the system.)
During unit operation, a cracking noise may be heard.This noise is
A cracking noise is heard
generated by the casing expanding or shrinking because of
temperature changes.
The is because the system circulates smells from the interior air
Smells are generated
such as the smell of furniture, paint, cigarettes.
During COOL or DRY operation, indoor unit may blow out mist.
Mist or steam are blown out
This is due to the sudden cooling of indoor air.
To avoid frosting on the heat exchanger of the indoor unit, the air
CO O L mo de cha n ges to FAN
conditioner sometimes changes to FAN mode in COOL operation.but
mod e aut om atic ally
immediately it will change back to COOL mode.
When unit is stopped, it won't restart immediately unit 3 minutes have
The system does not restart
elapsed to protect the system. When the electric plug is pulled out
immediately
and reinserted, the protection circuit will work for 3 minutes to protect
the air conditioner.
In HEAT mode, the outdoor
This is because the frost on the heat exchanger of the outdoor unit
unit generates water or steam.
is melting (in COOL operation) .
the fan motor of indoor unit will
For the sake of removing the remaining heat, the fan motor of
continue running even though
indoor unit will continue running for some time after the heat
operation's stop.
the HEAT operation is stopped.
In DRY mode, when room temperature becomes lower than temp.
In DRY mode, fan speed can't
c
setting +2
o
unit will run intermittently at LOW speed regardless
be changed.
of FAN setting.
Check the power supply: make sure the rated voltage is supplied.
Check if the residual current circuit breaker trip?(make sure cut off
None of the units operates
the power supply off and contact the service station immediately. )
The temperature displayed on
In consideration of the temperature difference in the room,
the control panel is different
the air conditoner will automatically compensate the temperature
In order to improve the comfortableness .therefore it is normal
from the temperature detected
phenomenon.
by the user
21