resideo S8910U3000 Manuel D'installation page 33

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

S8910U3000
CORRESPONDANCES
DES BORNES
S8910U
HS780
TERRE (BRÛLEUR)
6
TR (CLIP DE TERRE)
24 V (TERRE)
TERRE
VANNE (TERRE)
24V
TH
VANNE
VANNE
L2
L2
L1
L1
HSI
ALL.
HSI
ALL.
CAPTEUR
RS
CONTRÔLEUR
GAZ COMBINÉ
1
1
ALIMENTATION. PLACER SI NÉCESSAIRE UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES.
VEILLER À NE PAS INVERSER L1 ET L2.
2
EMPLACEMENT DU LIMITEUR AUXILIAIRE.
3
L'ÉLECTRODE DE DÉTECTION EST PRÉSENTE POUR LE MODÈLE À DÉTECTION À DISTANCE HS780. VOIR LE TABLEAU 2.
4
LORSQUE HS780 EST UN MODÈLE À DÉTECTION À DISTANCE, RETIRER LE CONNECTEUR RAPIDE DE CAVALIER DU S8910U.
COUPER LE FIL CAVALIER AU NIVEAU DE LA CARTE DE CIRCUIT ET LE JETER. BRANCHER LE FIL DE L'ÉLECTRODE DE FLAMME AU CAPTEUR.
VOIR LE TABLEAU 2.
5
COUPER LE CONNECTEUR RAPIDE DE 1/4 PO DU FIL ET LE REMPLACER PAR LE CONNECTEUR RAPIDE 3/16 PO (FOURNI).
6
UTILISER L'ADAPTATEUR DE TERRE VERT FOURNI POUR RELIER LA TERRE DU S8910U (BRÛLEUR) AU CHÂSSIS DE L'APPAREIL.
Fig. 3. Raccordement typique lorsque le modèle S8910U remplace le modèle Robertshaw HS780.
34-00008EFS—03
CONTRÔLEUR D'ALLUMAGE PAR INCANDESCENCE S8910U
S8910U Hot Surface Ignition
WARNING
Input Voltages = 120 & 24 VAC, 60 Hz
HSI = 120V, 5A max.
Valve = 24V, 2A max.
Explosion Hazard. Can cause
Total 24V Load = 0.4 + valve load
serious injury or death.
U.S. Patent 8,085,521
Disconnect power before ser-
Prepurge Time = 32 Sec.
vicing. This device can mal-
Igniter Warm Up Time = See Inst. Sh. 34-00008
function if it gets wet. Never
Ignition Trial Time - See Selection Tab
try to use a device that has
Number of Trials - See Selection Tab
been wet -- replace it.
Between Trial Time - 96 Sec.
6
TERRE DU
BRÛLEUR
MV
MV
THERMOSTAT
OU CONTRÔLEUR
Golden Valley, MN 55422
Assembled in Mexico
Selection Tab
LED States
ON
Trial count
Control Status
OFF
= 1 try (default)
Device damaged-
ON
Trial count
replace control
OFF
= 3 tries
Ignition lockout Red Blink
ON
Trial for ign. period
Normal operation
OFF
= 4 seconds (default)
Weak flame signal
ON
Trial for ign. period
See Instruction Sheet 34-00008
OFF
= 7 seconds
for additional states
1
2
3
4
120 VAC
120 VAC
See
NOTE: ALWAYS apply
NEUTRAL
HOT
LED
this control as instructed
States
in Instruction Sheet
34-00008
SYSTEM SETUP
5
LIMITEUR
2
12
Color Pattern
Red
Steady
®
Green
Steady
C
US
AUTO
Green
Blink
IGNITION
SYSTEMS
ANSI Z21.20
32304204-001 Rev. A
See
Instructions
for
CAPTEUR
Single/Dual
Rod
DE FLAMME
Applications
4
4 4
4
ALLUMEUR PAR
INCANDESCENCE
L1
(SOUS TENSION)
L2
1
MF8529