Pre-Installation Preparation; Minimum Clearance To Combustibles - Napoleon Oakdale EPI3-1 Série Manuel D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Clean all ashes from the inside of the existing appliance opening. Ensure the chimney and appliance are free of
cracks, loose mortar, creosote deposits, blockages, or other signs of deterioration. If necessary, have repair work
done by a qualifi ed professional before installing the appliance.
Do NOT remove bricks or mortar from the appliance. In case of an outside air inlet or ash dump, fi ll with
fi berglass insulation. Adhere to minimum clearances as illustrated.
2.1

minimum clearance to combustibles

MINIMUM CLEARANCES
A
Sidewall
B
Mantel
12" (30.5cm) Projection
C
Top facing
D
Side facing
E
Hearth (front)
F
Hearth (side)
MINIMUM APPLIANCE OPENING
G
Width (rear)
H
Width (front)
I
Height (front)
J
Height (rear)
Depth
K
L
Hearth depth
M Hearth width
N
Facing width
O
Facing height
Contemporary 45 1/2"
Mantel
Contemporary 45 1/2"
P
Q
Height of top
Contemporary 29 1/2"
surface
R
Side facing
S
Hearth (side)
T
Sidewall
12" (30.5cm)
16" (40.6cm)
16" (40.6cm)
6" (152mm)
Canada 18" (45.7cm)
USA 16" (40.6cm)
8" (203mm)
23" (58.4cm)
28" (71.1cm)
22" (55.9cm)
19" (48.3cm)
18" (45.7cm)
Canada 22" (55.8cm)
USA 20" (50.8cm)
46" (116.8cm)
54 1/2" (138.4cm)
(115.5cm)
Traditional 44 1/2"
(113 cm)
(115.5cm)
Traditional 44 1/2"
(113cm)
(74.9cm)
Traditional 28 1/2"
(72.3cm)
13 1/4" (33.6cm)
9" (22.8cm)
13" (33cm)

2.0 pre-installation preparation

EN
9
W415-2007 / A / 10.21.19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Epi3t-1Oakdale epi3c-1Oakdale epi3t-1Oakdale epi3tn-1

Table des Matières