• The key cannot be removed from the lock until the release lever is
returned to its initial position.
• To resume motorized control of the gate bring the release lever to its
initial locked position (FIG.18), then remove the key and stow it in a safe
place that is known only to persons authorized to use the gate. (FIG.
19).
5 PREPARATION FOR ELECTRICAL
CONNECTIONS
WARNING! To connect to the network, use a multipolar cable provided by
regulations by the book's unit.
• Perform the manual release as illustrated in heading 4.4.3.
• Remove the operator cover by undoing the 2 lateral screws and the
front screw located under the release lever (FIG. 3).
• Remove the cover upward (FIG. 3).
• Connect the yellow/green wire (earth) to the terminal eye already present
alongside the cable inlet hole (FIG. 20) (for models of class I).
• Route the wires to the electronic board located at the top of the operator.
• Make the connections as illustrated in the control unit manual.
• Refit the operator cover (FIG. 21).
6 TESTING
Each part of the automation system, e.g. safety edges, photocells,
emergency stop, etc. must be tested; follow the procedures shown in
the instruction manuals supplied with the devices in question. Perform the
following sequence of operations for testing of FORT:
• Check that all the prescriptions in this manual have been followed
scrupulously, with special attention to the matters set down in chapter 1
"General Prescriptions";
• Using the supplied control or stopping devices (key selector switch,
control pushbuttons or radio controls), perform gate opening, closing
and stopping tests and make sure the gate responds correctly to the
various commands.
• Check operation of all the system's safety devices (photocells, safety
edges, emergency stop, etc.) one by one.
7 PRODUCT MAINTENANCE
Maintenance must be carried out at regular intervals by qualified personnel
in compliance with the provisions of statutory legislation and the regulations
in force. FORT must be serviced at least once every 6 months or after
10,000 operating cycles since the last service.
• Disconnect the operator from all power supplies.
• Check all the moving parts and replace any worn parts.
• Check all parts of the automation system for signs of deterioration.
8 SPARE PARTS
Spare parts can be purchased by contacting the technical service.
9 DISPOSAL
At the end of its useful life the automation system must be dismantled by
qualified personnel and the materials must be recycled or disposed of in
compliance with the local legislation in force.
10 WARRANTY
Fratelli Comunello SpA provides a warranty for 24 months for the correct
functioning of the actuators from the date of manufacture, provided that the
performance specications indicated in the product instruction manuals are
respected. Free of charge repair and replacement of components that are
found to be faulty according to the indisputable judgment of the company's
technical staff shall be guaranteed at the sole discretion of Fratelli Comunello
Spa, and so excluding any claim for damages made by others. Warranty
material shall be returned to Fratelli Comunello S.p.a. headquarters carriage
paid and will then be shipped to the customer carriage unpaid. The material
found to be faulty and returned to Fratelli Comunello S.p.a. shall remain
property of the Seller. Any cost resulting from any work needed to repair
the defect or to replace the material shall be charged to the Buyer. No
compensation shall be allowed for the period of device inactivity. Work under
warranty does not prolong the warranty period. The defect of the product
shall be reported by the Buyer within 8 (eight) days from its discovery or
18
COMUNELLO ®Copyright 2015 - All rights reserved
from the date of delivery of the goods, under penalty of invalidation of the
warranty. Such claim shall be notied in writing.
Warranty does not cover:
Any product defect or damage that may have been incurred during
transport; any defect or damage arising from any fault and/or from neglect,
inadequacy and misuse of the electrical wiring in the Buyer's property; any
defect or damage caused by any repairs carried out by non authorised
personnel or by incorrect use/installation (with reference to this, system
maintenance is recommended every 6 months) or if not original spare parts
are used; any defect caused by chemicals or atmospheric conditions. The
warranty does not cover any cost neither for consumable materials nor for
alleged defects or convenient surveys.
Product Features Fratelli Comunello SpA products are subjected to
continue changes and improvements; their technical features and image
may therefore change without previous notice.
Competent court
Since the contract of sale is conrmed by an Order Conrmation drawn up
in Rosà, any such dispute shall be settled by the laws of Italy and by the
court of Vicenza (VI).