Technical Data; Accuracy; Ambient Conditions; Supply Voltage (External) - Balluff BTL7-V50T-M A-C003 Série Notice D'utilisation

Masquer les pouces Voir aussi pour BTL7-V50T-M A-C003 Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

BTL7-V50T-M _ _ _ _ -A/B/Y/Z(8)-C003
Micropulse Transducer - Rod Style
6

Technical data

6.1

Accuracy

The specifications are typical values for the BTL7-V50E...
at 24 V DC and room temperature, with a nominal length
of 500 mm in conjunction with the BTL-P-1013-4R,
BTL-P-1013-4S, BTL-P-1012-4R or BTL-P-1014-2R
magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Position resolution
Non-linearity with a constant
distance between the magnet and
profile:
Nominal length ≤ 5500 mm
Nominal length > 5500 mm
Hysteresis
Repeat accuracy
Temperature coefficient
1)
Velocity resolution
Min. detectable velocity
Max. detectable velocity
6.2

Ambient conditions

Operating temperature
Storage temperature
Humidity
Rod pressure rating (when installed
in hydraulic cylinders)
For Ø 8 mm
For Ø 10.2 mm
Shock rating
per EN 60068-2-27
3)
Continuous shock
per EN 60068-2-29
3)
Vibration
per EN 60068-2-6
3)
Degree of protection per IEC 60529
Connector C003 (when attached)
14
english
1 µm
±30 µm
±0.02 % FS
≤ ±10 µm
≤ ±5 µm
(typ. ±2.5 µm)
≤ 18 ppm/K
0.1 mm/s
1 mm/s
10 m/s
2)
−40°C to +85°C
−40°C to +100°C
< 90%, non-
condensing
< 250 bar
< 600 bar
150 g/6 ms
150 g/2 ms
20 g, 10 to 2000 Hz
IP 67
6.3

Supply voltage (external)

Voltage, stabilized
4)
Ripple
Current draw
(at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength
(GND to housing)
6.4

Output

Short-circuit resistance
6.5

Dimensions, weights

Rod diameter
Nominal length
For Ø 8 mm
For Ø 10.2 mm
Weight (depends on length)
Housing material
Rod material
Rod wall thickness
For Ø 8 mm
For Ø 10.2 mm
Young's modulus
Housing mounting via threads M18×1.5 or 3/4"-16UNF
Tightening torque
6.6
Maximum sampling rate f
At nominal length
0050 to 0250 mm
0251 to 0600 mm
0601 to 1300 mm
1301 to 2700 mm
2701 to 5500 mm
5501 to 7600 mm
> 7601 mm
Nominal length = 500 mm, magnet in the middle of the measuring range
1)
For
: Use in enclosed spaces and up to a height of 2000 m above sea
2)
level.
Individual specifications as per Balluff factory standard
3)
For
: The transducer must be externally connected via a limited-
4)
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
10 to 30 V DC
≤ 0.5 V
SS
≤ 120 mA to 1524 mm
≤ 160 mA from 1525 mm
≤ 500 mA/10 ms
Up to 36 V
Up to 36 V
500 V AC
Signal cable to GND
8 mm or 10.2 mm
25 to 1016 mm
25 to 7620 mm
Approx. 2 kg/m
Anodized aluminum
Stainless steel 1.4571
0.9 mm
2 mm
Approx. 200 kN/mm
2
Max. 100 Nm
max
780 Hz
710 Hz
600 Hz
460 Hz
245 Hz
180 Hz
170 Hz