7

Technical data

The information here comprises values at room
temperature in conjunction with magnetic tape
BML TSC-ALCZ-1ZZZ-M_ _ _ with a gap of 0.4 mm over
the magnetic tape (without cover strip).
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
7.1

Accuracy

Position resolution
Absolute
BML SL1-ALZ0-
U1ZZ- _U1L-_ _
Analog, incremental
real-time signal
BML SL1-ALZ0-
U1ZZ-AU1L
Repeat accuracy
Hysteresis
Max. non-linearity of sensor
head
Max. non-linearity
of entire system (sensor
head + magnetic tape)
Temperature coefficient of
the entire system
Movement speed
7.2

Ambient conditions

Operating temperature
Storage temperature
for sensor head
Shock rating
Continuous shock
per EN 60068-2-27
2)
Vibration load
per EN 60068-2-6
2)
Noise
per EN 60068-2-64
2)
Degree of protection per
IEC 60529 (with
screwed-on connector)
External magnetic fields
Humidity
www.balluff.com
≤ 1 µm
Period 2 mm
< 1 μm
≤ 1 μm
±5 μm
±15 μm
10.5 ppm/K
Max. 10 m/s
1)
–10 °C...+70 °C
–25 °C...+85 °C
100 g/6 ms
150 g/2 ms
20 g, 10...2000 Hz
20 g, 5...2000 Hz
IP67
– < 30 mT (to avoid
permanent damage)
– < 1 mT (to avoid
influencing the
measurement)
90% RH, condensation not
permitted
7.3

Supply voltage

Supply voltage
3)
IO-Link
Current draw
4)
Power consumption
Reverse polarity protection
Overvoltage protection
Dielectric strength
(GND to housing)
Switch-on delay (system
ready) after applying supply
voltage
7.4

IO-Link interface

Additional real-time output
BML S1L-ALZ0-
U1ZZ-A_ _ _
7.5

Dimensions, weights

Housing material
Weight (sensor head)
1)
For
: Use in enclosed spaces and up to a height of 2000 m above
sea level.
Individual specifications as per Balluff factory standard, resonant
2)
frequencies excluded
For
: The sensor head must be externally connected via a limited-
3)
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1 or a class 2 power supply as defined in UL 1310 or UL 1585.
Without controller current draw
4)
18...30 V
70 mA at 24 V
supply voltage
Approx. 1.4 W
No
No
500 V DC
100 ms
– Analog, incremental
real-time signal
– 1 Vss (sine, cosine signal),
2 mm period
Nickel-plated, chrome-
plated die-cast zinc
47 g