10.2
Code Fault Message
1 6
INVALID MODE CHANGE
PRESS ESCAPE KEY
18
CONFIG. FAULT: 18
PRESS ESCAPE KEY
19
CONFIG. FAULT: 19
PRESS ESCAPE KEY
20
CON FIG. FAULT: 20
PRESS ESCAPE KEY
21
CONFIG. FAULT: 21
PRESS ESCAPE KEY
22
CON FIG. FAULT: 22
PRESS ESCAPE KEY
23
CON FIG. FAULT: 23
PRESS ESCAPE KEY
24
CON FIG. FAULT: 24
PRESS ESCAPE KEY
2 5
CONFIG. FAU LT: 25
PRESS ESCAPE KEY
26
CON FIG. FAULT: 26
PRESS ESCAPE KEY
27
CON FIG. FAULT: 27
PRESS ESCAPE KEY
28
CON FIG. FAULT: 28
PRESS ESCAPE KEY
29
CON FIG. FAU LT: 29
PRESS ESCAPE KEY
30
CON FIG. FAULT: 30
PRESS ESCAPE KEY
31
CONFIG. FAULT: 31
PRESS ESCAPE KEY
32
CON FIG. FAULT: 32
PRESS ESCAPE KEY
33
CON FIG. FAULT: 33
PRESS ESCAPE KEY
34
CON FIG. FAULT: 34
PRESS ESCAPE KEY
35
CON FIG. FAU LT: 35
PRESS ESCAPE KEY
8 008 364/NB 86/25-04-00 © SICK AG • Safety Systems • Germany • All rights reserved
Diagnostic Messages

Error messages with unique allocation

Fault Description
Invalid mode change by the rotary switch.
No Country code was entered for the desired
operating mode.
Two muting pairs and single stroke restart are
selected.
Blanking attempted with a TYPE 2 Primary.
Reduced resolution with a TYPE 2 Primary.
Floating blanking is enabled without the American
Code entered.
More than 16 beams indicated for floating blanking.
Floating blanking was selected with PSDI.
Attempted to execute reduced resolution with
a 30 mm AOPD.
External Restart and Restart Interlock for
Secondary AOPD selected.
Single stroke Restart selected with PSDI.
Invalid reduced resolution mode for American
code entered with guard only.
Invalid reduced resolution mode for American
code entered with PSDI.
Invalid reduced resolution mode for European
code entered with guard only.
Invalid reduced resolution mode for European
code entered with PSDI.
One safety channel sent setup information of size 0.
One safety channel sent configuration information
of size 0.
Swedish Restart selected with external restart.
LCU-P programmed for PSDI mode with a PSDI timer
and external restart is selected.
GB
Chapter 10
353

Publicité

Table des Matières
loading