Operating instructions
LCU-P
5

Electrical installation

WARNING
8 008 364/NB 86/25-04-00 © SICK AG • Safety Systems • Germany • All rights reserved
Electrical installation
Cut power to the system!
To prevent unintentional start-up of the system, disconnect the
power during installation of the LCU-P.
The LCU operates with 24 V DC ± 20 % and has a current
consumption of 0.5 A (without load). Connection is potential-
free via two 33-pin plug-in terminal strips. This enables the
wiring to be carried out before the LCU is installed. The
terminals are designed for a max. wire cross-section of:
2
1 x 2.5 mm
with sleeve, or
2
1 x 4 mm
solid.
The extent of wiring depends on the particular application. The
principle connecting diagram is shown in fig. 5.
Configuration of Universal Inputs:
A 1 and A 2
muting
muting
muting
muting
Functions dependent on program settings
B 1 and B 2
– (open)
muting
single-stroke restart "latched restart"
single-stroke restart "unlatched restart"
single-stroke restart "latched restart"
single-stroke restart "unlatched restart"
GB
Chapter 5
327