W O L F
F R A M E D
The illustrations below provide installation
specifications for Model ICBCT15E.
If Model ICBCT15E is installed above cabinets,
the electrical placement is not critical. A
grounded electrical box should be located
within 1.2 m of the right rear of the cooktop.
For installation above an oven, unless you are
using cabinets deeper than 610 mm, it is
recommended that the electrical supply be
placed in the base cabinet to the right of the
oven.
I N S TA L L AT I O N S P E C I F I C AT I O N S – M O D E L I C B C T 1 5 E
533 mm
OVERALL
DEPTH
381 mm
OVERALL WIDTH
96 mm
127 mm
TERMINAL BOX
Overall Dimensions
M O D E L I C B C T 1 5 E
Overall Width
Overall Height
Overall Depth
Minimum Cabinet Depth
Minimum Height Clearance*
Cut-Out Width
Cut-Out Depth
*Minimum 146 mm clearance is required
between countertop and any combustible
surface directly below the cooktop.
For detailed terminal block dimensions,
refer to the illustration on page 7.
Dimensions may vary to ± 3 mm.
8
E L E C T R I C C O O K TO P S
M O D E L I C B C T 1 5 E
330 mm
max
51**
489 mm
mm
COOKTOP CUT-OUT
DEPTH
381 mm
96 mm
533 mm
NOTE: Application shown allows for installation of two 381 mm modules side-by-side with 838 mm recommended cabinet width. 457 mm
recommended cabinet width for installation of single 381 mm cooktop or module. *Minimum clearance from both side edges of cooktop cut-out
578 mm
to combustible materials up to 457 mm above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up
to 457 mm above countertop.
102 mm
340 mm
Countertop Cut-Out
489 mm
IMPORTANT NOTE: Do not block the cooling
fan located at the bottom of the cooktop.
838 mm
457 mm
51 mm*
min
340 mm
CUT-OUT TO
COMBUSTIBLE
COOKTOP CUT-OUT
64 mm
MATERIALS
min
(BOTH SIDES)
914 mm
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
381 mm
340 mm
COOKTOP CUT-OUT
64 mm
min
FRONT OF COUNTERTOP
RECOMMENDED
762 mm
CABINET WIDTH
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
WIDTH
ABOVE COOKTOP
102 mm
E
381
mm
WIDTH
489 mm
COOKTOP