Problem
Motor stops immediately after
starting.
Motor runs, but no suction.
Motor runs, but poor suction.
Motor stops during operation
Machine blows dust.
Abnormal sound from
machine.
EC Declaration of Conformity
We hereby declare that DC 1800/DC 2800 H EX is in compliance with the following directives and standards: 2006/42/EC,
2014/35/EU, 2014/30/EU, 2014/34/EU, EN 60204-1, EN 1822-1, DIN EN 60335-1 (11/2010), DIN EN 60335-2-69 (01/2010)
including annex AA and CC. The electrical connector supplied is intended for connection outside the zone. Appropriate electrical
connections must be used in the zone. The machine must not be used for explosive, unstable or self-igniting particles or dust with
a minimum ignition energy of (MIE) < 3 mJ. No hot or glowing particles may be sucked into the machine. The serial number and
year of manufacture are indicated on the rating plate of the machine. The machine must also be labelled as follows:
Dustcontrol AB
Anna-Lena Berg / CEO
2020-10-13
Cause
Incorrect fuse.
Suction hose not connected.
Suction hose perforated.
Blocked filter.
Suction hose too long or narrow.
Hose partially blocked.
Top of machine poorly fitted.
Dust trapped in cyclone.
Motor overheated
Filter loose or damaged.
Peter Söderling / Technical Manager
2020-10-13
1800/2800 H EX, Art.nr. Part 94169-K
Action
Replace with correct fuse.
Connect hose.
Replace hose.
Clean or replace.
Replace hose.
Reverse or clean hose.
Adjust fitting.
Remove top and clean cyclone.
Make sure the machine is not throttled and wait
for it to cool down (about 30 min)
Check and replace as necessary.
Book service.
23