30
Finalizing the Installation
Configuration OnTop Vent avec Verticalement Un coude horizontal peut
être utilisé
The termination must
fall within the shaded
area shown in the chart.
Use the indicated
restrictor and diffuser
positions.
Up to four elbows (45°
or 90°) may be used.
Only one horizontal
elbow may be used.
May use 8" (203mm) or
6-5/8" (168mm)
diameter vent.
© Travis Industries
40' (12m) max
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
10/20/2021 – 1481-FR
(for qualified installers only)
Exhaust Restrictor # 4
Intake Restrictor # 2
Diffuser Position # 2
H2
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
H1
This is considered a
vertical elbow
40' (12m) max
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
864 40K CF Install