Error messages:

Message
Unstable Welding
Voltage
Wire Feed Jam
Water Flow Too Low
Water Flow Detected
Description
The generator is unable to
deliver the pre-set value
(voltage) requested by the
wire feeder.
It can appears:
1.
During welding:
Motor is at maximum
power and is not able to
maintain the pre-set WFS
value.
The wire feeder has
detected:
No water flow.
Too low water flow
(less than 0.7
liter/min).
The wire feeder has
detected water flow while
the setting in select menu
is water cooler "no".
Misadjustment(s)
Check that welding pre-set
parameters (WFS and
Voltage) matches the
application (wire diameter,
thickness, gas...).
Check the polarity switch
position of the generator
correspond to the polarity
of the wire feeder
connection.
Check the remote control
switch of the generator set
on "Remote" position.
Check if pre-set
parameters are not above
the specified limit of the
generator.
Verify wire can move freely
in cable.
Verify spool brake is not
set too high.
Check if the water cooler is
on and filled up with
coolant.
Check the water circuit
including water cooled
torch connection.
The setting of water cooler
is wrong in the select
menu.
Note: In this case, flow meter
protection is not used.
A-11
Corrective Action
Adjust parameters.
Correct polarity switch
position and wire feeder
polarity connection.
Select "remote" position.
Reduce the parameters or
use an higher rating
generator.
Clean or replace the liner.
Adjust spool brake.
Fill up and switch on water
cooler.
Remove blockage in water
circuit.
Select the correct setting of
the water cooler in select
menu.