D. Memory Function - Saving, Reading and Erasing (LF 38 Only)
Description:
The Memory function can be used to recall up to 10 specific sets of welding parameters defined by the user. Once the
welding parameters have been defined, the following steps can be taken to write these parameters to memory.
Press the MEM button
KNOB 1:
Turn Right( ) or Left ( )
Select Memory # (status):
- Used
- Free
From 1 to 10
Release "MEM" button to exit.
Button "ENTER"
Status
"Free"
WRITE ?
Save the welding
parameters into the
selected memory #.
NO
READ ?
You can read the welding
parameters allready saved
into the selected memory.
NO
ERASE ?
Delete the welding
parameters allready saved
into the selected memory
NO
WRITE ?
Save the welding
parameters into the
selected memory #.
YES
YES
YES
YES
WRITE memory:
You will overwrite the new
welding parameters in the
choosen memory #.
A-7
Button "ENTER"
WRITE into memory:
The status of the memory
becomes "Used".
READ memory
ERASE memory:
If you confirm ERASE by pushing
the "ENTER" button, then all the
welding parameters will be
deleted and the memory status
will become "Free".