Fuse Replacement; Disposal - VOLTCRAFT VC-2020 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fuse replacement

Always adhere carefully to the safety instructions, if you replace fuses!
Make sure that only fuses of the type stated and of the rated current specified are
used as a replacement. Do not use improper or repaired fuses and do not bypass the
fuse holder - this could lead to fire or arc discharge .
All measuring inputs are protected against overload. The input sockets "V" and "5A" are secured with a
fine fuse each. If measuring is no longer possible, you have to exchange the fuse.
Proceed as follows to change the fuse:
- Remove all measuring leads and turn the multimeter off.
- Remove the rubber holster from the casing.
- Loosen the screws on the back of the casing and carefully pull off the
cover.
- Replace the corresponding high-performance ceramic fuse with a
new one of the same type and current value (see illustration in the
chapter Inserting and replacing the batteries")
VC -2020
F 0.5A / 600V fast-blow 5 x 20 mm (for V/mA socket)
F 5A / 600V fast-blow 5 x 20 mm (for 5A socket)
- Then, close the battery compartment lid carefully again.

Disposal

Old electronic devices are hazardous waste and should not be disposed of in the house-
hold waste. When the device has become unusable, dispose of it in accordance with the
current statutory regulations at the communal collection points. Disposal in the domestic
waste is not permitted!