Vetus DIESEL GHS4 Manuel D'utilisation page 59

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 96
Fault Finding Table
GHS6.5, GHS8, GHS14, GHS24, GLS6.5, GLS14 and GLS25
7 Load, generator gets too hot
Possible Cause
• Over-loaded.
• Voltage too high.
• Blocked air inlet or outlet.
• Hot air from engine and or
generator is being used
again as cooling air.
Solution
• Reduce the load by switch-
ing off some of your electri-
cal equipment.
• Adjust the Voltage Regulator
to the correct voltage.
• Clear the air inlet and outlet.
• Prevent recirculation of hot
air.
Fault Finding, generator
7
57

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ghs6.5Ghs8Ghs14Ghs24Gls6.5Gls14 ... Afficher tout

Table des Matières