Les langues disponibles

troubleshooting
EN
symptom
Lights or blower
won't function (if
equipped).
Flames are very
aggressive.
Appliance won't per-
form any functions.
34
W415-4001 / 08.11.21
problem
Control module switch in
wrong position.
COM switch is unplugged.
Door is ajar.
Venting action is too great.
No power to the system.
Receiver switch in wrong
position (if equipped).
Transmitter isn't operational.
test solution
-
Verify ON/OFF switch is in the "I" position which denotes on.
-
Verify "COM" switch is plugged into the front of the control
module.
-
Ensure door is secured properly.
-
Check to ensure venting is properly sealed or restrict vent
exit with restrictor plate. (Not available in all appliances).
-
Check breaker to verify it's in the "on" position.
-
Verify that the 3 position switch on the receiver is in the
remote position (middle).
-
Check battery power and battery orientation.