code table.
4.3

Eco Message parameter codes

Parameters
ECO
Message
param.
codes
The following codes will set the respective parameters, provided that they are sent to the transmitter in an additional information / message string starting with
the character "&" + code(s) (see the example).
RTD-Pt IEC a=.0385
RTD-Pt JIS a=.03916
RTD-Pt MIL a=.03920
RTD-Ni DIN a=.0618
RTD-Cu
Linear resistance measuremt.
Linear resistance measuremt.
Type of RTD circuitry
2-wire feed line resistance
Thermocouple Type C
Thermocouple Type D
Thermocouple Type E
Thermocouple Type J
Thermocouple Type K
Thermocouple Type L
Thermocouple Type N
Thermocouple Type R
Thermocouple Type S
Thermocouple Type T
Thermocouple Type U
Thermocouple Type B
Internal reference junction
Without reference junction
Ext. reference junction [°C]
Linear voltage measurement
Linear voltage measurement
Error signal [mA]
Mains filter [Hz]
Error delay [sec]
Trim status
(read-only)
Sensor line monitoring
/WM
(read-only)
Trimming reset
XCMFTRIM
Selection of read-out level
Selection of read-out level
Note:
As can be seen in the examples, space characters must be entered between the individual parameter codes in the Eco Message string.
Parameter programming is independent of the read-out level.
Short-circuit monitoring is automatically switched off when the set RTD sensor contains ≤ 5 Ω
Table 4-1
Eco message codes
32
Temperature Transmitter TH01, TH01-Ex, TH101, TH101-Ex
Additional
code value
PT
100...1000
PJ
steps of
or
10
PM
100
20
NI
50
CU
120
RL
RH
WN
2-wire, 3-wire or 4-wire
WR
0.00...15.00
TC
1...10
TD
No. of series-connected
TE
thermocouples
TJ
without No.: always 1
TK
TL
TN
TR
TS
TT
TU
TB
CI
CN
CE
-40.00...+85.00
VL
VH
FC
3.60 .. 23.60
MF
50 or 60
FD
3...31
/DT
W, D, WD
B, S, BS
&1
&2
Comment/Description
progr. meas. range ≤ 0...500 ohms, (low range) short-circuit monitoring autom. off
progr. meas. range ≤ 0...5 Kohms , (high range), short-circuit monitoring autom. off
only for RTD, with RTD programming, without indic. autom. 2-wire or WN2 active
optionally only for RTD 2-wire circuit or if WN2 code has been used before
internal reference junction or CI is always autom. active, without additional programming
internal reference junction or CI is always autom. active, without additional programming
internal reference junction or CI is always autom. active, without additional programming
internal reference junction or CI is always autom. active, without additional programming
internal reference junction or CI is always autom. active, without additional programming
internal reference junction or CI is always autom. active, without additional programming
internal reference junction or CI is always active, without additional programming steps
internal reference junction or CI is always autom. active, without additional programming
internal reference junction or CI is always autom. active, without additional programming
internal reference junction or CI is always autom. active, without additional programming
internal reference junction or CI is always autom. active, without additional programming
no internal reference junction or CI is autom. active, additional programming required
indication of constant for ref. junct. temp. in the range -40...85°C/e.g. &CE50
progr. measuring range ≤ -125...125 mV, (low range)
progr. measuring range ≤ -125...1200 mV, (high range)
sensor and device error – delay for error signalling in seconds
(e.g. loose contact detection – prevention of output signal step changes)
/DTW: 2-wire-feed line resistance programmed, /DTD: DA-trim programmed,
/DTWD: both trimmings programmed, /DT: no trimming programmed
/WMB : line break detection is active , /WMS: short-circuit monitoring is active,
/WMBS: both are active
DA converter trim and 2-wire feed line resistance are reset
transmitting "&1" selects the parameters of read-out level 1 for the next read command.
transmitting "&2" selects the parameters of read-out level 2 for the next read command
1)
Unit must be adapted for generic/universal commands
Programming
1)
1)
1)
1)
3KDE115000R4284
Read-
out
level
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
none
1
2