Introduction; Specifications; Product Registration; Important - Westinghouse iGen2200 Manuel D'utilisation

Masquer les pouces Voir aussi pour iGen2200:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INTRODUCTION

SPECIFICATIONS

Specifications
Running Watts: 1800
Peak Watts: 2200
Rated Voltage: 120V
Rated frequency: 60 Hz
Phase: Single phase
Total Harmonic
Distortion:
Engine Displacement: 80 cc
Starting Type: Recoil
Fuel Capacity: 1.14 Gallon (4.3 L)
Fuel Type: 87–93 octane*
Oil Capacity: 0.37 US qt (0.35 L)
Oil Type: 10W30
Spark Plug: E6RTC
Spark Plug Gap: 0.024 – 0.032 in.
Valve Intake
Clearance:
Valve Exhaust
Clearance:
AC Grounding System: Floating neutral
Voltage Regulator: Digital
Alternator Type: Permanent magnet
Maximum Ambient
Temperature:
Certifications:
*Ethanol content of 10% or less. DO NOT use E15 or E85.

PRODUCT REGISTRATION

For trouble-free warranty coverage, it is important to
register your Westinghouse generator.
You can register by:
• Completing and mailing the product registration card
included in the carton.
• Registering your product online at:
https://westinghouseoutdoorpower.com/pages/
warranty-registration
• Sending the following product information to:
Westinghouse Outdoor Power
Warranty registration
777 Manor Park Drive
Columbus, OH 43228
iGen2200
≤ 3%
(0.60 – 0.80 mm)
0.0031 – 0.0047 in.
(0.08 – 0.12 mm)
0.0051 – 0.0067 in.
(0.13 – 0.17 mm)
104°F (40°C)
• EPA
• CARB
• CSA Group
iGen2500
2200
2500
120V
60 Hz
Single phase
≤ 3%
98 cc
Recoil
0.98 Gallon (3.7 L)
87–93 octane*
0.37 US qt (0.35 L)
10W30
E6RTC
0.024 – 0.032 in.
(0.60 – 0.80 mm)
0.0031 – 0.0047 in.
(0.08 – 0.12 mm)
0.0051 – 0.0067 in.
(0.13 – 0.17 mm)
Floating neutral
Digital
Permanent magnet
104°F (40°C)
• EPA
• CARB
For Your Records
Date of Purchase:
Model Number:
Serial Number:
Place of Purchase:
IMPORTANT: Keep your purchase receipt for trouble-free
warranty coverage.
Westinghouse Outdoor Power Equipment, LLC | 3
NOTICE
This product is designed and
rated for continuous operation
at ambient temperatures up
to 104°F (40°C). If needed,
this product can be operated
at temperatures ranging from
5°F (15°C)–122°F (50°C) for
short periods. If the product
is exposed to temperatures
outside of this range during
storage, it should be brought
back within this range before
operation. This product must
always be operated outdoors
in a well-ventilated area and
away from doors, windows,
and other vents.
Maximum wattage and current
are subject to and limited
by such factors as fuel BTU
content, ambient temperature,
altitude, engine conditions, etc.
Maximum power decreases
about 3.5% for each 1,000 feet
above sea level, and will also
decrease about 1% for each
10°F (6°C) above 60°F (16°C)
ambient temperature.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Igen2500

Table des Matières