Housekeeping continued...
Before performing any Housekeeping tasks to this water heater, be sure to turn the unit off and disconnect
the power supply.
Vacuum around the water heater for dust, dirt and lint on a regular basis. Clean the water heater and
remote control by using a damp soft cloth with a few drops of mild detergent and gently wiping the
surfaces of the unit. Wipe any remaining moisture with a dry soft cloth.
To ensure sufficient ventilation and combustion air supply, proper clearances must be maintained. The
water filters should be cleaned on a monthly basis.
CLEANING THE WATER HEATER AND REMO TE CONTROL(S):
• Make sure the unit is OFF and the electrical power supply has been disconnected.
• DO NOT scrub the appliance with a brush.
• Use only mild soapy water, other cleaners may damage the surface of the water heater.
• DO NOT remove any label including the rating plate while cleaning or servicing.
• DO NOT splash water on the remote controls when cleaning.
DANGER: Shock Hazard. Make sure the electrical power to the water heater is off to avoid potential
serious injury or damage to components.
DANGER: Combustible materials, such as clothing, cleaning materials, or flammable liquids, etc.,
must not be placed against or next to the water heater.
Vacation and Extended Shut-Down
If the water heater is to remain idle for an extended period of time, the power and water to the appliance
should be turned off.
The water heater and piping should be drained if they might be subjected to freezing temperatures.
After a long shut-down period, the water heater's operation and controls should be checked by qualified
service personnel.

Anti-Freezing

While the Anti-Freezers will help to protect from cold temperatures, they will in no way guarantee
protection from freeze damage. DO NOT rely on the Anti-Freezers to fully protect the unit from freezing,
take all precautions to prevent cold damage.
NOTICE: The
anti-freezing
device works
for the water
heater unit only,
and not for the
inlet and outlet
water pipes.
Draining Procedure
When the temperature falls below 32°F, water in your plumbing system or water heater can turn to ice and
then expand causing damage to the water heater. This damage is not covered under your manufacturer's
warranty. If these conditions are anticipated, please drain the water heater as follows to help but not
guarantee from freezing:
1. Shut off the main gas valve and power
2. Shut off the inlet water valve
3. Open all faucets
4. Take off the drain valve, and allow water to drain for 3 minutes or until the unit is empty.
5. Making sure all water is out, replace the drain valve, and shut off the faucets.
Product Support: Eccotemp.com/help-desk
* Freezing anywhere in the plumbing system can result in damage to the
water heater, such as a rupture in your Heat Exchanger. All pipes must be
adequately protected from freezing.
Units with Anti-Freezers have an automatic heating device and will help
to avoid freeze damage, but the power must be kept on. Freezing will occur
with no power. In very cold areas and when the temperature is under 32°F, or
in event of an ice storm, freezing will occur as the heating power limit is
exceeded.If these conditions take place, please follow the procedures
explained below.