GAS WALL OVEN INSTALLATION INSTRUCTIONS
6. Provide an Adequate Gas Supply
Important: Read these instructions carefully before
connecting this unit to a gas supply.
The units covered in these instructions are desi-
gned to operate on natural gas at 4" of manifold
pressure or on LP gas at 10" of manifold pressure.
A convertible pressure regulator is connected in se-
ries with the manifold of the wall oven unit and must
remain in series with the supply line, regardless of
which type of gas is being used.
For proper operation, the maximum inlet pres-
sure to the regulator must not exceed 14" of water
column (W.C.) pressure.
To check the regulator, the inlet pressure must be
at least 1" (or 3.4 kPa) greater than the regulator
pressure setting. If the regulator is set for 4", the
inlet pressure must be at least 5". If the regulator is
set for 10", the inlet pressure must be at least 11".
A manual shut-off valve must be installed on the
gas supply line external to the unit and where it can
be easily reached for the purpose of turning the gas
to the unit on and off. The recommended location
for the shut-off valve is in the cabinet beneath the
installation cutout (see Figure 8).
10" Min
(25.4 cm Min)
27
/
" Max
1
2
(69.9 cm Max)
Figure 8
The gas supply line to the unit should be ½" (1.3
cm) or ¾" (1.9 cm) pipe.
Close all openings in the cabinet cavity that en-
closes this unit. All openings around gas service
outlets must be closed at the time of installation.
7. Connection to Gas
Pressure Regulator
Adaptor or Union
Cabinet Base
External Shut-Off Valve
BEFORE CONNECTING THE UNIT
Remove all packing material and literature from
wall oven before connecting gas and electrical sup-
ply to the appliance.
Remove the storage drawer by pulling the drawer
out to the stops. Lift the drawer front to clear the
stops and pull it out.
The fuel regulator on this appliance has a built-in
shut-off valve. Make sure the valve is UP in the
OPEN position (see Figure 10).
Valve location
6
(see Figure 9)
Shut-Off Valve
Solid Pipe Or
Flex Connector
Figure 9
Front of oven
Figure 10a