GAS WALL OVEN INSTALLATION INSTRUCTIONS
1. Carpentry
Refer to Figure 1 for the dimensions applicable to
your appliance, and the space necessary to receive
the oven. Corners must be square.
Floor cabinet must be able to support 150 pounds
and must be flush with bottom of opening.
Oven support surface must be solid plywood or
similar material. MDF (medium-density fibreboard),
particle board, or laminated woods are not to be
used as base support.
2. Connect Electricity to Gas Wall
Oven
For personal safety, these appliances must be
properly grounded.
This appliance is equipped with a
three-prong grounding plug for your protection
against shock hazard and must be plugged directly
into a properly grounded receptacle. Do not cut or
remove grounding prong from this plug.
120 volt, 60 Hertz, properly grounded dedicated
circuit protected by a 15 amp circuit breaker or time
delay fuse.
Do not use an extension cord with this range.
10" Min
(25.4 cm Min)
27
/
" Max
1
2
(69.9 cm Max)
Figure 2
22"
(55.9 cm)
The wall receptacle should be located in the cabinet
beneath the installation cutout. The receptacle
should be easily accessible for service and removal
of power from appliance (see Figure 2)
The wall receptacle and circuit should be checked
by a qualified electrician to make sure the recep-
tacle is properly grounded.
Preferred Method
Grounding
type wall
receptacle
Where a standard 2-prong wall receptacle is instal-
led, it is the personal responsibility and obligation
of the consumer to have it replaced by a properly
grounded 3-prong wall receptacle.
Do not, under any circumstances, cut or re-
move the third (ground) prong from the power
cord.
If an external electrical source is used, the ap-
pliance, when installed, must be electrically groun-
ded in accordance with local codes or in their
absence of local codes with the National Electric
Code ANSI/NFPA No. 70-1987 or latest edition.
Check all code rules and regulations for connecting
the wall oven to be certain the installation conforms
with all local, municipal and state codes as well as
local utility regulations.
Failure to comply with the above could result in a
serious shock hazard.
Note: All hook-ups and adjustments shall be perfor-
med by qualified technicians.
Disconnect electrical supply cord from
wall receptacle before servicing wall oven.
3
Do not, under
any circumstances,
cut, remove,
or bypass the
grounding prong.
Power supply cord with
3-prong grounding plug
Figure 3