JP3
10 -
Open and Door input common wire
11 -
N.O. Contact OPEN (controls manual door opening)
12 -
Contact DOOR (door status input)
NC – Door closed NO – Door open
(detects the status of the door needed to identify the alarm
condition; if not used, leave the jumper connected)
JP2 (COMPASS-READER connection)
13 -
+ Power supply
14 -
Date 1
15 -
Date Ø
16 -
Power supply
17 -
Led A
18 -
Led B
Receives from COMPASS-READER the data of the card inser-
ted.
It is possible to connect a maximum of 2 COMPASS-READERs to
each COMPASS-485 (Fig. 3).
5) GENERATION OF MASTER CARDS
The system is controlled by three Master Cards (Master Card +,
Master Card -, Master Card Jolly) which activate or deactivate the
cards and configure the functioning of access as indicated in the
paragraph "Configuration of the Parameters and Management
of the Cards"
To generate the Master Cards, proceed as follows:
1
Open the COMPASS-485 box
2
Set the Dip Switch 6 to ON (Fig.3)
3
Show a Standard Card (the Led will flash changing from red
to green continuously)
4
Set the Dip 6 to OFF
5
The Card has now become a Master Card +, attach the supplied
special adhesive label (green colour, symbol +) which will help
to identify the type of Master Card.
6
Set the Dip Switch 7 to ON (Fig.3)
7
Show a Standard Card (the Led will flash changing from red
to green continuously)
8
Set the Dip 7 to OFF
9
The Card has now become a Master Card -, attach the supplied
special adhesive label (red colour, symbol -), which will help to
identify the type of Master Card.
10 Set the Dip Switch 8 to ON (Fig.3)
11 Show a Standard Card (the Led will flash changing from red
to green continuously)
12 Set the Dip 8 to OFF
13 The Card has now become a Master Card Jolly, attach the
supplied special adhesive label (yellow colour, symbol Jolly),
which will help to identify the type of Master Card.
14 Close the COMPASS-485 box.
The Master Cards therefore allow the configuration of the sy-
stem.
After using the Master Cards, place them in a safe place known only
by assigned personnel along with the instructions for use.
6) CONFIGURATION OF THE PARAMETERS AND MANAGE-
MENT OF THE CARDS
The configuration of the parameters and card activation are obtained
by showing the sequence of the Master Cards and Cards to be
activated or deactivated observing the following procedure:
• Card activation:
Show the Master Card + to the reader (the Led will flash chan-
ging from red to green continuously) followed by the card for
which access activation is required (the Led turns to yellow)
• Card deactivation:
Show the Master Card – to the reader (the Led will flash changing
from red to green continuously) followed by the card for which
access deactivation is required (the Led turns to yellow)
INSTALLATION MANUAL
If it becomes necessary to deactivate a card that has been
mislaid there are two ways of doing so:
• Free Access (door always open):
Show the Master Card Jolly to the reader (the Led will flash
changing from red to green continuously) followed by the Master
Card + (the Led turns to green)
• Access Forbidden (door always closed):
Show the Master Card Jolly to the reader followed by the
Master Card - (the Led turns to red)
• Access with normal operation mode
(opening with memorised cards only):
Show the Master Card Jolly to the reader for two consecutive
times (the Led turns to yellow).
• Setting of Door Relay Operation Time:
Show the Master Card + to the reader (the Led will flash chan-
ging from red to green continuously) followed by the Master
Card Jolly (the green Led flashes), from now on every time the
Master Card Jolly is shown the value of the door relay operation
time, expressed in seconds, will increase. The sequence of
values is the following:0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,1
5,16,17,18,19,20,21,22,23,24,25.After 25 which is equal to
25s, the value goes back to 0.
If the value set is 0, the relay for door opening remains active
until the door is closed.
• Setting of Door Control Time:
Show the Master Card – to the reader (the Led will flash chan-
ging from red to green continuously) followed by the Master
Card Jolly (the red Led flashes), from now on every time the
Master Card Jolly is shown the value of the door control time,
expressed in seconds, will increase.
The sequence of values is the following: 0,10,20,30,40,50,60,7
0,80,90,100, 110,120,130,140,150,160,170,180,190,200,210,
220,230,240,250. After 250 which is equal to 250s, the value
goes back to 0. If the value set is 0, the door control is disa-
bled.
Door check:Checks the status of the door using the "DOOR"
contact input, ensuring that after the door opening relay is
closed, the door is actually opened and then closed again.If
opening does not occur after the "door check time", the alarm
relay is commuted.If the door is opened, it must be closed
again within the "door check time", otherwise the alarm relay
is commuted.
• System reset:
WARNING! This procedure deletes all activated cards and
Master Cards automatically; the operation parameters
remain memorised.
Show the Master Card three consecutive times (the Led will
flash changing continuously from red to yellow). Deletion takes
90 sec. approximately.
NOTE: after showing a Master Card, the system waits for a
subsequent card for 3 seconds, after which it goes back to
normal operation.
7) DIP SWITCH CONFIGURATION
The COMPASS-485 control includes 8 dip-switches, which can
be configured to ON - OFF:
The Dip Switches 1-2-3-4-5 allow the setting of the communication
address (polling) of the Compass-485 when used with Compass-
232 and PC.
If the system is controlled by Securbase and the card code
is known (all cards are supplied with a printed 6-digit code),
deactivation can be obtained by using the card software
and entering the code to be deactivated in the appropriate
menu.
If the system is not controlled by Securbase or the card
code is not known, it is necessary to deactivate all of the
cards and then reactivate all valid cards.