Warning: Always disconnect the unit from the mains before any maintenance or repair work is
carried out.
1. Remove the two screw covers (11) and the
screws (10).
2. Remove the entire top panel (9).
3. Remove the three threaded bolts (6) securing
the upper hinge plate (5) on the right-hand
side.
4. Carefully lift up the door and place it on a
suitable surface to protect it from scratches.
5. Take off the protective corner-piece (7) and
re-fit it in the groove on the right-hand side,
pushing it firmly down.
6. Remove the hinge pin from the upper hinge
plate (5) and screw it back in from the
opposite side.
7. Remove the two screws from the left-hand side in the upper hinge plate mounting and re-fit
them on the right.
8. Remove the three screws (1) holding the lower hinge plate (2) on the right-hand side.
9. Remove the hinge pin from the lower hinge plate and re-fit it in the next hole.
10. Remove the adjustable foot (4) from the left-hand side and re-fit it on the right.
11. Attach the lower hinge plate (2). Do not tighten the screws for the moment.
12. Replace the door in its new position. Ensure that the hinge pin is inserted into the guide bushing
(hole) on the lower part of the door frame.
13. Attach the upper hinge plate (5) (removed earlier in step 3) on the left-hand side. Ensure that the
hinge pin is inserted into the guide bushing (hole) on the upper part of the door frame. Do not
tighten the screws for the moment.
14. Adjust the closed door to its proper position and tighten the screws of the upper and lower hinge
plates.
15. Replace the top panel (9).
16. Replace the screws (10) und the screw covers (11) in the top panel (9).
17. Put the unit back in its intended position and wait for about two hours before connecting it to
the mains.
Freezer compartment door
1. Open the door
2. Insert a screwdriver into the slot under the lower hinge, push the spring up and hold it.
3. Remove the door and hinge assembly.
4. Take off the protective cover from the left-hand side and re-fit it in the opening on the right-
hand side.
5. Turn the door round 180°, place the lower hinge onto the lower door pin and insert the upper
door pin into the upper hinge.
6. Now slide the lower hinge into the corresponding opening, ensuring it locks into place.
Temperature control
The unit is re-activated by connecting it to the mains. It is only switched off
completely when the plug is removed from the wall socket.
The temperature in the refrigerator cabinet can be adjusted by setting the
16