Les langues disponibles

Mounting and securing
6.5
Adjusting electrical hold-open device
Open door leaf to desired hold-open angle and fix it there (1.).
X
Remove cable protection foils from guide rail (2.).
X
Loosen clamping screws of electrical hold-open device (3.).
X
Move electrical hold-open device until catch contacts sliding block (4.).
X
Screw down electrical hold-open device securely (5.).
X
To prevent loops from forming, tighten cable and fasten cable protection at hold-open device end (6.).
X
Store cable in cable protection and in upper cable chamber behind electrical hold-open device (7.).
X
Secure stored cable with cable protection foil (8.).
X
CAUTION!
Check free upward movement of the rocker!
X
9.
If necessary, the holding force can be adjusted (9.). According to EN 1155, the release torque should
amount to 40 Nm - 120 Nm for a door with 90° hold- open angle.
6.6
Mounting cover panel
Clip on cover panel.
X
CAUTION!
Do not pinch cable.
X
GB 6
TS 5000 E BG
Fig.: 6.5.1