Mounting and securing
Mark out and drill fixing holes for door closer and guide rail using fitting template or cut M5 thread
X
if necessary.
Drill additional hole (A) for 24V DC power supply.
X
In case this product is in use with an hold-open device, please observe the document "Instructions for
Installation, Commissioning, Operation and Maintenance of the GEZE Hold-Open Device FA GC" as well.
6.2
Mount guide rail and end caps
The cable connection must point to the pull side
Align spacers on guide rail (1.).
X
Fix guide rail in place (tightening torque: 2 Nm) (2.).
X
Align end caps and screw it on (3.).
X
Mount door closer according to instructions (4.).
X
All screwing torques are to be adjusted on site, if necessary.
GB 4
TS 5000 E BG
Fig.: 6.2.1