6.3
Mount sliding lever and connect with sliding block
Close closing-time valve (1.).
X
Set sliding lever in place (2.).
X
Turn sliding lever about 45° to position the notch (3.).
X
Remove sliding lever (4.).
X
Now the sliding lever can be appropriately attached to the notch.
Align and fit sliding lever with notch (5.).
X
Fix sliding lever (tightening torque 14 Nm) (6.).
X
Connect sliding lever to sliding block (tightening torque 5 Nm) (7.).
X
Open closing-time valve again (8.).
X
6.4
24V connection
Connect 24 V cable to lustre terminal. Electrical hold-open device is powered.
X
red = "+" (terminal 1)
white = "-" (terminal 2)
2.
45°
3.
1.
5.
6.
5.
4.
8.
Mounting and securing
7.
SW 3
Fig.: 6.3.1
Fig.: 6.4.1
GB 5