Safety Features

 Overheat: The appliance will automatically shut
down when the appliance exceeds a predetermined
temperature.
 Flame Failure: The appliance will automatically
shut down if the burner flame is extinguished.
 Power Failure: The appliance will shut off the gas
if it loses electrical power.

Appliance Specifications

Application
Min. Supply Gas Pressure
Max. Supply Gas Pressure
BTU/hour input
BTU/hour output
General Description
Operation
Gas Connection
Gas Control
Burners
Temperature Control
Temperature Range
Ignition System
Flue System
Humidifier Tray
Electrical Connection
Standby Power
Weight
Noise Level
AFUE Rating
Rinnai is continually updating and improving products. Therefore, specifications are subject to change without
prior notice.
The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating
conditions and was determined independently of any installed system.

Specifications

EX17CT
Approved for manufactured home (USA only) or mobile home or residential installation
convertible for use with natural gas and liquefied petroleum gases (propane / LPG)
when provision is made for the simple conversion from one gas to the other.
Approved for commercial setting.
Approved for installation at altitudes up to 10,200 feet (3109 m).
Natural Gas
3.5 in(89 mm) W.C.
10.5 in(267 mm) W.C.
Low 8200 High 16700
Low 6560 High 13360
Forced combustion, forced convection, flued gas furnace
Push button electronic
1/2 in male NPT
Electronic
Stainless steel Bunsen burner
Electronic thermostat, (Low, 60-80ºF in 2ºF increments, High)
Low, 60 - 80°F (in 2°F increments), High
Electronic spark ignition
The flue must be terminated to atmosphere with only flue components listed with the
appliance's certification. Warranty will be voided if non listed components are installed.
Capacity - 2.1 pints (1000 cc)
AC 120V, 60 Hz, 46 watts
0.5 watt
57 lbs (26 kg)
33-38 dB
Natural Gas: 81%
Rinnai Corporation EX17CT, EX22CT Manual
 Power Surge Fuse: A glass fuse on the PC board
protects against overcurrent. If the fuse blows then
all indicator lamps will be off.
 Spark Detector: The appliance automatically shuts
down if there is an abnormal spark at ignition.
 Fusible Link: In case the overheat feature does
not prevent an overheat then the fusible link could
break, shutting off the appliance.
Low 8200 High 21500 Low 8200 High 20700
Low 6560 High 17200 Low 6560 High 16560
AC 120V, 60 Hz, 56 watts
33-42 dB
Propane: 82%
Natural Gas: 80%
EX22CT
Propane Gas
8.0 in(203 mm) W.C.
13.0 in(330 mm) W.C.
Propane: 82%