Wall-Mounted Installation - Hayward 7019071 Guide De L'utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1

Wall-mounted installation

Fix the box and the measuring chamber on the wall (optional). The box must be installed in the equipment room (dry,
temperate, ventilated). Caution, acid vapours can cause irreversible damage to your device. Position the treatment product
tanks accordingly.
The Control Station must be fitted a minimum horizontal distance of 3.5 m (or more, if required by local regulations) from
the pool.
The box must be placed vertically on a flat surface, with the cables downwards. As this box is also used to evacuate heat
(heat dissipation from internal components), it is important that the four sides of the box remain unobstructed. Do not to
install the Control Station behind a panel or in an enclosed space.
Before installing the control unit in the intended location, check that the power cord can reach the protected outlet.
Disconnect the pool filtration pump before starting the installation. The system must be installed in accordance with the
standards currently in force in the country of installation. The control box must be fitted a minimum horizontal distance of
3.5 m (or more, if required by local regulations) from the pool, within 1 m of a protected outlet. Install and use the product
at an altitude below 2000 m.
The flow switch must be installed on the return pipe directly in line with and upstream of the treatment product injection
point. Allow a 25 cm straight section before the flow switch. A hole should previously have been drilled in the pipe to allow
the flow switch to pass through. Screw the flow switch into the saddle clamp, taking care to seal with Teflon. Then install
the clamp on the pipe. The flow switch must be installed in the direction of operation to ensure that it is tripped by the flow
from the filtration pump.
The device used to inject the treatment products (acid, etc.) must be installed last on the water return line, after any equipment
(heater, etc.). A hole should previously have been drilled in the pipe to allow the treatment product to pass through. Install the
saddle clamp and screw the injection valve into the saddle clamp using the adapter provided. Seal with Teflon.
Use the transparent PVC hose for suction (between the tank and the peristaltic pump) and the semi-rigid white polyethylene tube
for injection (between the peristaltic pump and the injection valve).
All the metal components of the swimming pool can be connected to the same earth as per local regulations
USE ONLY GENUINE REPLACEMENT PARTS
Page 5 of 20
Control Station
Rev. A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aquarite +

Table des Matières