GB
1.
ELECTRIC MOTOR : VARIANTS
STOPPING
1.1 Depress RED Button
(or on/off toggle
switch if tted to the Off
position) to stop mixer
(Fig B).
STARTING
1.2 Lift rear door.
1.3 Feed supply cable out
through the rear of the
mixer and plug into
power supply.
1.4 Depress GREEN
Button (or on/off toggle
switch if tted to the On
position) to start mixer
(Fig A).
-
Ensure supply cable is safely stored before moving mixer.
-
Keep rear door shut when mixer is running
EMERGENCY STOP
1.5 Depress large RED Button, situated on top left hand side of power unit housing (Fig C).
2.
YANMAR (ELECTRIC START)
STOPPING
2.1 Press Red Lever (Fig D).
2.2 Turn Ignition Key Anti-
Clockwise (Fig J)
-
Note: Red indicator light
glows when engine charging
system fails.
-
Ensure that when machine
is not in use that ignition is
switched OFF, or battery
failure may occur.
EMERGENCY STOP
2.3 Pull the handle on the
side of the power unit box to
STOP the machine (Fig E).
COLD STARTING
2.4 Lift rear door.
-
Open fuel cock if tted (Fig F).
2.5 In cold starting situations the engine requires 2cc of engine oil (10w-30) to be applied using oil applicator. The oil
should be inserted into the engine by removing the rubber plug on the priming port, ensure the plug is replaced (Fig G).
2.6 Ensure the Emergency Stop Button is pushed in (Fig H).
2.7 Set the engine speed lever (situated on the left hand side of engine) to the run position (Fig I).
2.8 Turn Ignition Key Clockwise until Engine turns over, release key when engine starts. If engine fails to start, repeat process of cold
start.
-
Note: Once an attempt to start the engine has failed, before re-trying the key must be turned back to the OFF position.
-
DO NOT operate with rear door open.
WARM STARTING
2.8 Repeat process above from 2.5.
Operating Instructions
10
A
B
C
E
D
Closed
Open
F