Table 1 Summary of faults
[...] LED does not light up
☼ [...] LED lights up
Led status
Control Module:
[Power On]
Control Module:
[Bar ON] &
ThunderION(s):
[ON]
Control Module:
☼ [Bar Fault]
ThunderION(s):
☼ [Fault]
Control Module:
☼ [Bar Fault] &
ThunderION(s):
[Fault]
Or:
Control Module:
[Bar Fault] &
ThunderION(s):
☼ [Fault]
ControlModuleThunderION_UM_9752160020_NL_D_GB_F_V1_1
Cause
No mains voltage.
Control Module switched off
Fuse in Control Module
blown
Control Module faulty
ThunderION(s) not
connected
Control Module - Bar
connecting cable faulty
Control Module is in remote
position; an I/O connector is
not connected
Control Module is in remote
position, Remote on Bar
contacts are not activated.
Control Module is in remote
position; an I/O connector is
wrongly wired.
ThunderION faulty
Control Module faulty
ThunderION(s) placed too
close to conducting parts
ThunderION(s) heavily fouled See ThunderION user manual
ThunderION(s) faulty
Control Module - Bar
connecting cable faulty
ThunderION(s) faulty
Control Module faulty
Solution
Switch on mains voltage
Switch on Control Module mains
switch
Replace fuse (3.15 AT, 250 V)
Return Control Module for repair
Connect ThunderION(s)
Repair connecting cable
(See Section 4.4.1.)
Place Control Module in local
position or connect I/O connector
(See Section 4.4.2.1.)
Restore input signals for Remote on
Bar.
(See Section 4.4.2.)
Connect I/O connector wiring
according to Section 4.4.2.
See ThunderION user manual
Return Control Module for repair
See ThunderION user manual
See ThunderION user manual
Repair connecting cable
(See Section 4.4.1.)
See ThunderION user manual
Return Control Module for repair