6.2. Remote/local switch set to remote

When the Control Module is switched on, [Power ON] and [Remote ON] should light up.
With the remote/local switch in the remote position, the ThunderION output voltage is switched
with the aid of a control voltage (10–30 V). This voltage must be supplied via the I/O connector
(see 4.4.3.1.).
If 0 V is supplied, the corresponding ThunderION is switched off and the associated [BAR ON]
LED does not light up. If 10–30 V DC is supplied, the corresponding ThunderION is switched on
and the associated [BAR ON] LED lights up.
The "Bar Operating OK" function can be remotely controlled for each ThunderION. If it is
operating correctly, voltage is present at the Bar Operating OK outputs of the I/O connector.

7. Maintenance

Keep the Control Module clean and dry.
The Control Module does not contain any parts that require maintenance.

8. Faults

Warning:
 When carrying out work on the equipment, disconnect the power supply.
 The work must be carried out by a skilled electrical fitter.
Depending on the configuration, the cause of a fault can be found in five places, namely:
-the ThunderION(s)
-the wiring between the ThunderION(s) and the Control Module
-the Control Module
-the I/O connector wiring
-peripherals connected to the I/O connector, e.g. a PLC
ControlModuleThunderION_UM_9752160020_NL_D_GB_F_V1_1