Connecting Bar Operating Ok; Commissioning; Functional Check; Remote/Local Switch Set To Local - Simco-Ion ThunderION Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Connect the remote ON/OFF power via the I/O connector 0 V must be connected to Pin 9
(remote ON common cathode)
The switch voltage must be connected to:
Pin 1 for bar 1
Pin 3 for bar 2
Pin 5 for bar 3
Pin 7 for bar 4
(see also the circuit diagrams in the appendix)
If 0 V is supplied, the corresponding ThunderION is switched off, if 10–30 V DC is supplied, the
corresponding ThunderION is switched on. This control voltage is present on the I/O connector
(Pin 11 + Pin 12), but can also be supplied externally.

4.4.3.2. Connecting Bar Operating OK

Connect Pin 10 (Bar Operating OK common collector) to the voltage to be switched (max. 30
V). (This voltage is present on the I/O connector (Pin 11 + Pin 12), but can also be supplied
externally. This voltage must be present at the open emitter of the optocoupler when the correct
output voltages are present on the ThunderIONs.
Open emitters (Bar Operating OK):
Pin 2 for bar 1
Pin 4 for bar 2
Pin 6 for bar 3
Pin 8 for bar 4
(see also the circuit diagrams in the appendix)

5. Commissioning

 Check whether all cables have been connected correctly.
 Switch on the voltage for the power unit or insert the plug into the wall socket.
 Switch on the Control Module.

6. Functional check

6.1. Remote/local switch set to local

When the Control Module is switched on, the [Power ON] LED and [Local ON] should light up.
The [Bar ON] LEDs should light up if the corresponding ThunderIONs are connected.
If a [Bar Fault] LED lights up, this means that the corresponding ThunderION is generating
insufficient or no high voltage. This may be caused by short-circuited or fouled emitters (see the
ThunderION user manual).
The "Bar Operating OK" function can be remotely controlled for each ThunderION. If it is
operating correctly, voltage is present at the Bar Operating OK outputs of the I/O connector.
GB