Making Your Own Cables; Connecting The Control Module - Simco-Ion ThunderION Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.4.1.2. Making your own cables

It is also possible to make the cables yourself. 6x AWG20 unshielded wire is recommended.
The connectors can be delivered separately by SIMCO (Nederland) B.V., namely:
-6-pole (bar) Control Module connector
-6-pole ThunderION connector
This cable must be wired 1:1, i.e. Pin 1 to Pin 1, Pin 2 to Pin 2 etc. (See Fig. 1)
Fig. 1 Layout of 6-pole connectors: Control Module + ThunderION

4.4.2. Connecting the Control Module

Route the mains connecting cable to the (mains) supply connection point such that it cannot
suffer mechanical damage.
 Connect up the connection cable as shown in Fig. 2, or fit a plug.
Fig. 2 Mains cable connection
ControlModuleThunderION_UM_9752160020_NL_D_GB_F_V1_1
Simco item No. 4510140125
Simco item No. 6603060120
PIN Function
1
+24 V
2
Remote ON/OFF +
3
HV OK open collector
4
HV OK open emitter
5
Remote ON/OFF -
6
0 V
(chassis front view).
GB
25

Publicité

Table des Matières
loading

Table des Matières