10-15X
4. PROGRAMMING and OPERATION
Programming the bell push-button
• Programming of the bell push-buttons is described in detail in the manual of the system
power supply (10-801, 10-802 or 10-806) or of the service unit (10-870).
• If you use the service unit, tear off the serial number to be found behind the nameplate under
the white foil of the external unit or the packing box, and stick it on the installation diagram.
• You can program up to 2 internal units in the memory location of each bell push-button. If
you want to program more internal units, you will need to apply master-slave progamming
to the internal units, as described in the service unit or internal unit manual.
• A non-programmed bell push-button will switch the light relay of the power supply.
General operation
If everything has been connected correctly and power up is applied, the LED of the external
unit will light up.
When picking up the receiver of an internal unit, communication with the external unit
should be possible at all times.
If you press a:
• non-programmed bell push-button, you will hear a high beep and the light relay of
the power supply is operated
• programmed bell push-button, you will hear the bell ringing at the external and the
internal unit.
Adjusting the volume on the external unit
There are 2 potentiometers under the nameplate with which you can adjust the volume
on the external unit.
Potentiometer for loudspeaker (volume on external unit)
Potentiometer for microphone (volume on internal unit)
Setting times
By default, the following times are programmed:
Speech time after initiating a call .............................................. max. 2 min
Time that a call from an external unit remains indicated .............. 2 min
You can also set other times via
• the power supply. For more information on programming via the power supply, see
manual of the power supply.
• the service unit. For more information on programming via the service unit, see manual
of the service unit (10-870).
• the relay
28
EN