10-15X
1
➥
Remove the vandalproof nameplate.
2
➥
Mount the external unit on the wall. The
recommended installation height for the
loudspeaker is 150 to 160 cm from the
ground. In order to avoid water entering
the device via the cable, it is best to
run the cable from the bottom up in the
device.
3
➥
Connect the wiring as shown in the con-
nection diagram on page 31.
Note
• In a single system, use the same colour code for the same terminals (a, b, P, ...) for
all products of the Access Control Standard range.
4
➥
You can fill out the provided blank namecards and insert them
behind the white plastic foil of the nameplate.
5
➥
Reinsert the nameplate into the external unit.
Connecting an extra door opener relay
A door opener relay can optionally be connected to the external unit between terminals R
and P. This relay must be present in the following cases:
• if several external units are used
• if the external unit is to be provided with a local door opener contact
Relay 10-835 can be placed in a flush mounting box behind the external unit.
a b
P R
EN
Relais
10-835
2-wire
1
3
a b
P R
3-wire
2
Relais
10-835
27