Custom Device Name

Net-X II a custom device name, do the following:
To assign the
1.
Use the knob to select 1. Custom Device Name.
2.
Press the knob.
3.
If there is no name set for this product, press the knob. If there is a name set for this product, use
the knob to select which letter to edit, then press the knob.
4.
Use the knob to select the letter, number or symbol, from A–@. There are 63 options.
5.
Repeat until the name is set as desired.
6.
Use the knob to select either Enter to save the name, or Cancel to exit without saving.
7.
Press the knob.

Set IP Mode

The Net-X II can use a pre-set static IP address, or it can be set manually.

Static IP

To set the Net-X II to a pre-set static IP address, follow the instructions below:
1.
Use the knob to select 2. Set IP Mode.
2.
Press the knob.
3.
Use the knob to select 1. Static IP.
4.
Press the knob.

Manual IP

To set the IP address manually, do the following:
1.
Use the knob to select 2. Set IP Mode.
2.
Press the knob.
3.
Use the knob to select 2. Manual IP.
4.
Press the knob.
5.
The manual IP address can be set from 000.000.000.000 to 255.255.255.255 by using the knob
to scroll and select the desired numbers 000–255 for each byte (set of three numbers). Use this
process to set each of the four bytes.
6.
Use the knob to select Enter to save the chosen IP address or Cancel to exit without saving.

Set Netmask

To set the Netmask, follow the instructions below:
1.
Use the knob to select 3. Set Netmask.
2.
Press the knob.
3.
Use the knob to select one of the following options:
A. 255.000.000.000
B. 255.255.000.000
C. 255.255.255.000
Exit (to cancel).

Operating Mode

The Net-X II can operate as a splitter/converter, or a DMX merger. To switch between the 2 modes, do the
following:
1.
Use the knob to select 4. Operating Mode.
2.
Press the knob.
3.
Use the knob to select either 1. 8 Port (used to activate RDM over Ethernet support for transport
of RDM to/from lighting fixtures via 5-pin DMX to a lighting controller via Ethernet, e.g. Art-Net™,
Art-RDM) or 2. 2 + 8 Port (required for DMX splitter mode via the 2 male DMX ports on the back
of the NET-X II; disables all RDM functionality; adds DMX Input A & B under the Set DMX Port
menu option).
4.
Press the knob.
5.
3. Exit (to cancel).