Adjusting the date and time The date and time are displayed in the format dd.mm.yyyy hh:mm. Select the
number to be changed over the > < and > < buttons.
Corrections can be made using the > + < and > - < buttons. The menu can be exited again using the > <.
The clock is supplied with power by an internal battery so that this can also run after being disconnected
from the mains power plug.
Language
Adjusting the language. Select the desired language using the >arrow upwards< and >arrow downwards<
buttons and confirm using the >OK< button.
Parameter
The password-protected area. Settings can be made on the device in this menu point which have effects
on the device properties and functions (e.g. welder code, scan site-code, traceability, ...). Entries and
functions can be enabled or disabled for the user and therefore sequences prescribed at the construction
site. The PIN code is pre-allocated on the works side with "12345". Please alter the password as needed
(see sub-menu point "Password"). The menu can be left at any point using the >END< button.
Welder code
Entry of the welder code can be activated or deactivated here (for a description see Chapter 7.3). The
status can be altered by pressing the >CHANGE< button.
If the option "Welder code" is activated then a valid welder code according to ISO-12176-3 is needed to
start a welding sequence.
Traceability Fitting
Entry of the traceability of the fitting can be activated or deactivated here or set as an optional entry (for
a description see Chapter 7.3). The status can be altered by pressing the >CHANGE< button.
Traceability Pipes
Entry of the traceability of the pipes can be activated or deactivated here or set as an optional entry (for a
description see Chapter 7.3). The status can be altered by pressing the >CHANGE< button.
Owner
The owner of the device (e.g. the company name) can be altered here. The change takes place manually
(see also the Chapter "Data entry").
Erase ALL Logs
This where all stored welding sequences can be deleted.
Attention! The whole memory is deleted. Partial deletion of the stored welding sequences is not
possible.
Page 28