Glass break detector
Installation requirements
Mount the detector between the protected glass and any heavy window coverings that
may be present. When heavy window coverings are present, the detector can be
mounted on the frame of the window.
Do not mount the detector:
•
On posts or pillars
•
In rooms with noisy equipment (air compressors, power tools, etc.), if this equipment
is operated when the detector is armed
•
Where the detector's view of the glass may be obstructed intentionally
How to install
1.
Orient the microphone for the best line-of-site to the protected glass. If ceiling
mounted the end with the microphone should face the protected glass.
2.
Open the sensor.
3.
Screw the base to the wall.
4.
Hold the batteries in place and pull out the battery
tab to power up the sensor.
5.
Close the sensor.
23