6
Safety Notes
6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6 The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms.
• Hansgrohe mixers can be used together with hydrauli-
cally and thermically controlled continuous flow heat-
ers if the flow pressure is at least 0,15 MPa.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Fault
Mixer stiff
Mixer dripping
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
4
English
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
max.. 70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective, sedimentation
- Hot water limiter incorrectly set
- Crossflow
Assembly see page 31
Symbol description
Do not use silicone containing acetic acid!
To adjust the hot water limiter on single lever
mixers, please see page 33. No adjustment
is necessary when using a continuous flow
water heater.
Dimensions (see page 34)
Flow diagram
(see page 34)
Operation (see page 35)
Cleaning
Cleaning recommendations, see enclosed
brochure.
Spare parts (see page 36)
Test certificate (see page 35)
Remedy
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter