Safety Notes; Installation Instructions; Technical Data; Flow Diagram - Hansgrohe Focus 31657000 Mode D'emploi / Instructions De Montage

Table des Matières

Publicité

6 6
6

Safety Notes

6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6 The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• The fitting must be installed, flushed and tested after
the valid norms.
• Prior to installation, inspect the product for transport
damages.
After it has been installed, no transport or surface
damage will be honoured.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
• Hansgrohe mixers can be used together with hydrauli-
cally and thermically controlled continuous flow heat-
ers if the flow pressure is at least 0,15 MPa.
• The product is exclusively designed for drinking water!
4
English
Symbol description
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Assembly see page 5
Adjustment
To adjust the hot water limiter on single lever
mixers, please see page 8. No adjustment
is necessary when using a continuous flow
water heater.
Do not use silicone containing acetic acid!
Dimensions (see page 9)

Flow diagram

(see page 9)
with EcoSmart
®
without EcoSmart
®
Operation (see page 10)
• Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a pro-
longed period of non-use.
• After periods of prolonged non-use, but
at least every third day, the fittings must
be opened with the handle in hot and
cold position to prevent stagnation in the
connecting lines. Let the water run until the
water temperature is constant.
Spare parts (see page 11)

Special accessories

special tool 58085000 (order as an extra)
Installation putty (order as an extra)
seal 98996000 (order as an extra)
Cleaning (see enclosed brochure)
Test certificate (see page 12)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Focus 31735000Focus 31738000Focus 31928000

Table des Matières