5
PA Power Amplifier
These instructions are intended for installers
with specific knowledge in sound reproduc-
tion using 100 V technology . Please read the
instructions carefully prior to installation and
keep them for later reference .

1 Applications

The amplifier PA-1500D with a rated output
power of 500 W is specially designed for
applications in PA systems . It is equipped with
a line level input for background music and
standard announcements . A second line level
input is provided for emergency announce-
ments or other important announcements .
A separate switch or an external relay can be
used for switching over to the second input .
2 Overview
Note: To make handling easier, all green terminal
strips can be disconnected from their plug-in con-
nections .
1 LED indicators
FAULT
will light up to indicate a fault in the
amplifier
PROTECT
will light up to indicate overheating or
a fault in the amplifier
CLIP
will light up to indicate overload
[turn back the volume control LEVEL (12)
or (17)]
SIGNAL
will light up when a specific signal level
is reached
ON power LED
STAND BY
will light up when the amplifier is
connected to the 230 V mains and is
switched off with the power switch (3)
PRIORITY
will light up when the connection
PRI CTL (16) is used to switch over
the amplifier to the input PRIORITY
INPUT (18)
SLEEP
will light up when there is no input
signal and the amplifier is in the sleep
mode to save power
2 Reset button (recessed) for the protective
circuit
3 POWER switch
4 Ground connection
GERMANY
T6.3AL
POWER
REMOTE
FUSE
6
7
5 Mains jack for connection to a mains
socket (230 V/ 50 Hz) via the mains cable
provided
6 Support for the mains fuse;
always replace a blown fuse by one of
the same type
7 Connection POWER REMOTE for an ex-
ternal switch used for remote-controlled
activation/deactivation
Note: When using the remote control feature,
make sure that the amplifier has not been
switched on with the POWER switch (3) .
8 Connection 24 V ⎓ for a 24 V emergency
power supply unit
9 Fuse for the 24 V power supply;
always replace a blown fuse by one of
the same type
10 Speaker terminals
11 Connection for the internal relay: The
relay will respond when the connection
PRI CTL (16) is used to switch the amplifier
to the input PRIORITY INPUT (18) .
12 Volume control LEVEL for the input PGM
INPUT (13)
13 Balanced line level input PGM INPUT
for standard announcements and back-
ground music
14 DIP switches
No. 1 to activate / deactivate the automatic
sleep mode to save power (chapter 6,
step 6)
No. 2 to activate / deactivate the 200 Hz
high-pass filter (for attenuating the low
frequencies in order to improve speech
intelligibility)
No. 3 for module PA-6FD (accessory,
chapter 4)
lower position ON: without PA-6FD
upper position: with PA-6FD
15 LED indicator: will light up to indicate cor-
rect operation of the amplifier
16 Connection +24V / GND for the 24 V aux-
iliary voltage, current rating: 0 .1 A
Connection PRI CTL / GND for a prior-
ity switch: When the switch is closed,
the amplifier will switch from the input
PGM INPUT (13) to the input PRIORITY
INPUT (18)
17 Volume control LEVEL for the input PRI-
ORITY INPUT (18)
18 Balanced line level input PRIORITY INPUT
for important announcements – also see
items 16 and 17
19 Cover plate; will be removed when the
fault detection module PA-6FD is installed
500
WRMS
24 V /35.5 A
BALANCED
OUTPUTS
FUSE RATING
T40AL
40
8
9
10
BALANCED
OUTPUTS
PA-6FD
FAULT DETECTION MODULE
PRI
PGM
FD/PRIORITY
PRIORITY
RELAY
INPUT
CONTROL
INPUT
12
17
OUT
PRI
OFF: FAULT
G
CTL
ON: NORMAL
24V
GND
PA-6FD
LEVEL
LEVEL
1 2 3
ON
0
10
0
10
0dBu (0.775 V)
200 Hz
CONTACT
0dBu (0.775 V)
MAX 0.1A
MAX 1A
30 kΩ BAL
SLEEP
30 kΩ BAL
11
13 14 15 16
18

3 Safety Notes

This unit corresponds to all relevant directives
of the EU and is therefore marked with
WARNING The unit uses dangerous
mains voltage . Leave servicing
to skilled personnel only and
never insert anything into the
air vents: Risk of electric shock!
During operation, there is a hazard of con-
tact with a dangerous voltage of up to 100 V
at the speaker terminals
BALANCED
OUTPUTS
switch off the amplifier before making or
changing any connections .
The unit is suitable for indoor use only . Pro-
tect it against dripping water, splash water
and high air humidity . The admissible ambi-
ent temperature range is 0 – 40 °C .
Do not place any vessel filled with liquid on
the unit, e . g . a drinking glass .
The heat produced inside the unit must be
dissipated by air circulation . Never cover
the air vents of the housing .
Immediately disconnect the mains plug
from the socket
1 . if the unit or the mains cable is visibly
damaged,
2 . if a defect might have occurred after the
unit was dropped or suffered a similar
accident,
3 . if malfunctions occur .
In any case, the unit must be repaired by
skilled personnel .
Never pull the mains cable to disconnect
the mains plug from the socket, always
seize the plug .
For cleaning only use a dry, soft cloth; never
use water or chemicals .
No guarantee claims for the unit and no
liability for any resulting personal damage
or material damage will be accepted if the
unit is used for other purposes than orig-
inally intended, if it is not correctly con-
nected or operated, or if it is not repaired
in an expert way .
If the unit is to be put out of oper-
ation definitively, take it to a local
recycling plant for a disposal which
is not harmful to the environment .