Error Messages And Error Clearance; Technical Data - Weller Zero Smog TL Traduction De La Notice Originale

Masquer les pouces Voir aussi pour Zero Smog TL:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
sounds again the next time the unit is turned on, the
filter must be changed.
If no action is taken, the filter unit will cut out after five
minutes in order to avoid overheating.
When changing the main filter the filtration time can be
reset as follows:
Keep the UP/DOWN buttons pressed and, at the same
time, turn on the switch until an audible signal sounds.
Release the buttons, wait 5s and turn the unit off. Wait
another 5s and turn the unit on. Filtration time is now
reset.
Cleaning
To ensure that the unit functions properly, the nozzle,
extractor arm and connecting hose must be cleaned
on a regular basis.

Error messages and error clearance

Message/symptom
Extraction power missing
Unit is not running
Device does not work
Sub-micron paricle becoming dirty
to quickly

Technical Data

Solder fume extraction
Dimensions L x W x H
Weight
Mains supply voltage
Power consumption
Operating sound level from 1 m
distance
Maximum vacuum
Maximum quantity supplied
Gas filter
Pre filter
Combined filter
Possible cause
Pipe system leaking
Filter is dirty
Thermally switched off
Fuse is blown
Unit is not properly connected
Pre-filter has not been used
Zero Smog TL
mm
335 x 330 x 445
inch
13.19 x 12.9 x 17.52
kg
9
(V/Hz) 230 / 50 (FT91013699)
120 / 60 (ZEROSMOGTL)
(V/W) 230/110
120/110
db(A) 53
(Pa/V) 3000
(m³/h) 190
l
2,5
Filter F7 collects 40-60% fine dust > 1 mm.
Combined H13 high efficiency submicron filter (99.95 % particle sepa-
ration upto 0.12 μm)
in combination with an activated carbon filter
Warranty
Claims by the buyer for physical defects are time-
barred after a period of one year from delivery to the
buyer. This does not apply to claims by the buyer for
indemnification in accordance with §§ 478, 479 BGB
(German Federal Law Gazette).
We shall only be liable for claims arising from a warranty
furnished by us if the quality or durability warranty has
been furnished by use in writing and using the term
„Warranty".
The warranty shall be void if damage is due to improper
use and if the device has been tampered with by unau-
thorised persons.
Subject to technical alterations and amendments.
For more information please visit www.weller-tools.
com
Remedial measures
Reseal the pipe system
change the filter
Leave the unit to cool down. Switch
on again after approx. 3 hours.
Please contact our Customer
Service: technical-service@
weller-tools.com
Check the electrical connections
Use a pre-filter Fit an F7 filter Use
a preliminary seperator if the
proportion of solid matter is high.
GB
ENGLISH
17

Publicité

Table des Matières
loading

Table des Matières