ISO/TR11638-1995
Measured sound pressure level Lwa = 81.2 dB
Measured Sound Power Level: LWA = 101.2 dB
Guaranteed Sound Power Level: LWA = 104 dB
The given values are emission values and do not therefore
represent safe values in the place of work. Although there is
correlation between emission and pollution values, they
cannot be a reliable basis for deriving whether or not
additional preventive measures are necessary. The factors
that may influence the immediate pollution value in the
place of work include the duration of effects, specific
features of the place of work, other noise sources, e.g.
number of appliances and other neighbouring processes.
Reliable values in the place of work may also differ in
various countries. However, this information is to help the
user better estimate the risk and threat.
Warranty
Warranty claims as per the warranty certificate attached.
General Safety Instructions
The instruction manual should be read thoroughly before
the first use .If in doubt regarding the connection and
operation, contact the manufacturer (servicing department)
TO SECURE A HIGH DEGREE OF SAFETY, OBSERVE
THE FOLLOWING INSTRUCTIONS:
Caution!
Caution: Operation is allowed with stray current
protection switch only. Kindly ask your electrician
1.
The operator shall be held liable for accidents
and dangers caused by the third persons to
themselves or to their property.
2.
Keep children and domestic animals at a safe
distance from the running unit (6 metres as a
minimum).
3.
Always wear safety anti-skid shoes, gloves,
safety goggles and long trousers when working
with this unit.
4.
When using the unit in dusty conditions, wear a
protection face guard .
5.
Don't point the vac at other persons´ faces Keep
hands, feet, hair and your garments away from
any openings and moving parts.
6.
Never wear loose garments or jewellery that
could be drawn in the air inlet. Always check the
unit and see whether it is assembled properly
before putting in on.
7.
Never use the vac in rainy or wet weather.
8.
Check the main power line on a regular basis and
if some parts are found to be damaged, have
them replaced at a professional servicing facility
or by a qualified repairman.
9.
Keep all the handles and grips dry and clean.
10. Keep all the handles and grips dry and clean.
11. Never leave the machine running while it lies on
the side. It has been designed to be operated in
a vertical position only.
12. Never pick up any burning materials, such as
cigarette ends and charcoal remains.
13. Do not pick up flammable, toxic, or explosive
materials Do not use this unit to pick up wet
leaves or debris
14. Do not use the suction mode unless the collection
bag is fitted. .
15. Do not travel the unit in operation on roads and
gravel paths.
16. Do not put anything in the inlet opening by hand.
17. Wear safety goggles while working the unit.
Emergency Action
Apply appropriated first help and call a qualified medical help as
fast as possible
Protect the injured from more injuries and calm him/her down.
Assigned Use
The leaves vac is allowed to use for leaves and garden waste –
grass and small branches .
The manufacturer shall not be made liable for damages if the
provisions of general applicability and of this manual are not
observed.
The leaves vac has been designed for private use . The units for
private use in house and garden are those used there but not in
public facilitates, parks, sports grounds, in agriculture and forestry. .
Disposal
Disposal instructions are given by picturegraphs placed on the unit
and packaging. Description of individual meaning is to be found in
the chapter "Symbols on Unit" .
Operator Requirements
Before the use of the unit, the operators are required to read the
instructions of use carefully.
Qualification
No special qualification is required for use of the unit except for
detailed direction by a professional.
Minimum Age
Only persons above 16 years of age are allowed to work with the
unit.
Exempted from the provision is the use of the juvenile trainees if
they work in the course of their professional training with an aim to
obtain the skill under trainer supervision.
Training
Use of the unit requires adequate lesson by a professional or the
use of the manual only. Special training is not required.
Technical Data
Voltage
Frequency/Protection type
Protection class :
Maximum output:
Motor speed:
Air speed
Composting ratio :
Suction and blowing volume : ca. 14 m³/min
Connection cable :
Vibration level:
Collection bag volume :
Weight :
Ordering No.:
Voltage
Frequency/Protection type
Protection class :
Maximum output:
Motor speed:
Air speed
Composting ratio :
Suction and blowing volume : ca. 14 m³/min
Connection cable :
Vibration level:
Collection bag volume :
Weight :
Ordering No.:
9
230 V
50 Hz / IP 20
II
2500 W / P1
-1
14.000 min
270 km/h
10:1
350 mm / H05VV-F
2
1,318 m/s
35 l
ca. 4,3 kg
94052
230 V
50 Hz / IP 20
II
2500 W / P1
-1
8.000-14.000 min
270 km/h
10:1
350 mm / H05VV-F
2
1,318 m/s
35 l
ca. 4,3 kg
94056